Currently Available Facilities and Tests/Modes
at
SAIF-Chandigarh

Name of the Facility Available Test/Mode
BET Surface Area Analyzer
(BET Analyzer)
BET surface Analyzer
Particle Size Analyzer with Zeta Potential
(DLS-(ZETA))
Particle Size(DLS)
Zeta Potential
particle size + Zeta Potential
FEG Scanning Electron Microscope
(FEGSEM)
FESEM
EDS With High/Low Magnification(FE-SEM)
MAPPING (FE-SEM)
FT-NMR Spectrometer
(FTNMR)
1D- 1H NMR (CDCl3 / D2O)
1D 1H NMR(DMSO-d6)
2D COSY (CDCl3 / D2O)
1D- 13C NMR (CDCl3 / D2O)
1D- DEPT Experiment (CDCl3 / D2O)
2D-HSQC (CDCl3 / D2O)
2D-ROESY (CDCl3 / D2O)
2D-TOCSY (CDCl3 / D2O)
2D-HMBC Experiment (CDCl3 / D2O)
1D - D2O Exchange
1D-13C NMR (DMSO-d6)
1D-DEPT EXPERIMENT (DMSO-d6)
2D-COSY (DMSO-d6)
2D-NOESY (DMSO-d6)
2D-HSQC (DMSO-d6)
2D-ROESY (DMSO-d6)
2D-TOSY(DMSO-D6)
2D-HMBC EXPERIMENT(DMSO-d6)
1D- APT Experiment (CDCl3 / D2O)
1D-APT EXPERIMENT (DMSO-d6)
2D NOESY Experiment (CDCl3 / D2O)
Laser Ablation Inductively Coupled Plasma Mass Spectrometer
(ICPMS)
ICPMS Standardization
Sample Preparation
Liquid Chromatograph Mass Spectrometer
(LCMS)
MASS
LCMS
MS-MS
HRMS
SYNAPT XS MALDI TOF - Protein intact Mass by UPLC MS
MALDI TOF/TOF- Protein identification by MS/MS for gel band and gel spots
MALDI TOF/TOF - sequencing of Peptides using Bio Lynx software (for pure peptide only) (direct infusion)
MALDI TOF/TOF - Molecular weight confirmation/accurate mass determination.
MALDI TOF/TOF - Polymer analysis etc.
MALDI TOF/TOF - Ion Mobility Study to separate reverse peptide or isobaric compounds using Drift scope Software
MALDI TOF/TOF - ETD compounds study.
Liquid Nitrogen Plant
(LN2)
LIQUID NITROGEN
Microscope with Image Analyzer
(MIA)
MICRO PHOTOGRAPHY
Polarimeter
(POLM)
Polarimeter
Scanning Electron Microscope
(SEM)
IMAGING
SEM Specimen preparation Critical Point Dryer
(SEMDRYER)
Critical Point Dryer
Maldi SYNAPT XS HD Mass Spectrometer
(SYNAPT-XS)
Protein intact Mass by UPLC MS
MALDI TOF/TOF- Protein identification by MS/MS for gel band and gel spots
Protein Profiling for complex mixture using 2D Nano-LC. (LC/MS/MS)
sequencing of Peptides using Bio Lynx software (for pure peptide only) (direct infusion)
Molecular weight confirmation/accurate mass determination.
Polymer analysis etc.
Ion Mobility Study to separate reverse peptide or isobaric compounds using Drift scope Software
ETD compounds study.
Transmission Electron Microscope
(TEM)
IMAGING
Grid
Thermal Analyzer (DSC, TGA)
(TGA-DSC)
DSC-RT- 650oC
TGA/DSC- RT-750oC
TGA/DSC-RT-1650oC
TGA RT-2400oC
TEM Specimen preparation Ultramicrotome UC7
(ULTRAMICROUC7)
Tissue cutting(Including stain Grids)
X-Ray Fluorescence Spectrometer (WD-XRF)
(WDXRF)
SOLID/POWDER
LIQUID
X-Ray Diffractometer (Powder)
(XRDPOWDER)
SCANNING