Currently Available Facilities and Tests/Modes
at
SAIF-Mumbai

Name of the Facility Available Test/Mode
CHNSO Elemental Analyzer
(CHNSO)
C H N S Estimation
Oxygen Estimation
Dynamic Mechanical Analyzer
(DMA)
Positive Temp. (above RT upto 600 0C)
Negative Temp ( below RT upto -150 0C )
Differential Scanning Calorimetry (DSC)
(DSC)
RT- <400 0C
RT- <600 0C
RT- 700 0C
Low Temp. -80 to 25 0C (RT)
Low Temp. -150 to 25 0C (RT)
Cp Measurement (RT- 400 0C)
Electron Spin Resonance Spectrometer (JEOL)
(ESRJEOL)
X-band Room Temperature
X-Band Variable Temperature -1700c to +2000c
X-Band Liquid nitrogen temp. (77K) )
X-Band # Single crystals using Goniometer room temperature measurement
Q-Band Room Temperature
FEG Scanning Electron Microscope
(FEGSEM)
SEM Image (Surface OR Cross Section)
SEM Image (Surface + Cross Section)
EDS
EDS Mapping
WDS
WDS Mapping(For 3 element maps)
Focused Ion Beam -Scanning Electron Microscope
(FIBSEM)
SEM Imaging / EDS Analysis
TEM Lamella preparation
FIB Patterning
FIB Slice and View
FT-IR Imaging System
(FTIRIMG)
Routine Spectrum
Single Point Spectra (micro -ATR/Grazing angle /Normal reflectance and Transmittance mode)
Focal Plan Array
FAR-IR
GC-HR Mass Spectrometer
(GCHRMS)
GC MS (EI +ve or -ve )
Headspace GCMS
GC with FID detector
HR LC-MS/MS (Q-TOF)
(HRLCMS)
Only HRMS
HRMS + compound formula and library search
LCMS with library (Plant extract Impurity Profiling Metabolite Identification or Degradation studies or Environmental samples)
Amino acid sample preparation
HPLC with PDA detector for amino acid profiling
HPLC + PDA detector + HRMS Spectrometer with library
HPLC with PDA detector
Field Emission Gun-Transmission Electron Microscope 300 Kv
(HRTM300)
Imaging
EDS (Spectrum only)
Mapping
Line Scan
EELS
EDS (spectrum with image)
Laser Ablation ICP Mass Spectrometer
(ICPMS)
Standardization and Estimation
Subsequent sample per element
Liquid Chromatograph Mass Spectrometer
(LCMS)
HPLC with PDA detector
Nuclear Magnetic Resonance Spectrometer 600 MHz
(NMR600)
1H-CDCl3
1H-DMF
1H-Any other Solvent
X-nuclei-CDCl3
X-nuclei-DMF
X-nuclei-Any other Solvent
2D-NMR-CDCl3
2D-NMR-DMF
2D-NMR-Any other Solvent
Solid State
High Resolution Orbitrap Liquid Chromatograph Mass Spectrometer
(OHRLCMS)
HRMS + compound formula & library search
LCMS with library (Plant extract or Impurity Profiling or Metabolite Identification or Degradation studies or Environmental samples)
Protein Identification (for 1-hour)
Sample Preparation (In-gel or In-solution Trypsin Digestion with Desalting)
Only HRMS
Lipidomics
Protein Identification (for 2-hours)
Only desalting of digested protein samples
Intact Mass of Proteins Peptides and Oligonucleotides
Small-angle X-ray scattering
(SAXS)
SAXS Analysis
With Flow Cell
With Shear Cell
At High Pressure
With Tensile stage with humidity
Secondary Ion Mass Spectrometer
(SIMS)
Depth Profile
Spectrum mass /Elemental Mapping study
Stylus Profilometer
(STYL-PRO)
Stylus Profilometer
3D Scan(Mapping per Hour)
Simultaneous Thermogravimetric Analysis (TGADTA)
(TGADTA)
RT-600
RT-800
RT-1000
RT-1200
RT-1450