1 | Chromatography |
|
HPLC
|
Perkin Elmer
Series 200
|
Diode array detector;
RI detector System;
Size exclusion chromatography for molecular weight estimation; Column switching accessory
|
Separation and detection of different components of complex mixtures; Qualitative/quantitative analysis.
|
Working
|
Technical Staff : Ms. Daxa Patel
Contact No : 02692-234966
Email Id : sicart_cvm@hotamil.com
|
|
Gel Permeation Chromatography
|
Perkin Elmer 200
|
Range: 580-107 mw;
PLGEL calibration standard (Polystyrene)
|
Analysis of molecular weight distribution in polymers, resins, oils, aligomers and organic compounds.
|
Working
|
Technical Staff : Mr. Dipen Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
2 | Mass Spectrometry |
|
GC-Mass Spectrometer
|
Perkin Elmer
Turbomass
|
Mass range: upto 650 amu; Programmable
pneumatic control for
carrier gas flow regulation;
NIST Mass spectra library
|
Ionization modes: EI, CI modes of operation;
Separation/identification of organic/ organometallic compounds, pesticides, volatile oils etc.
|
Working
|
Technical Staff : Dr. Mokshapani Tiwari
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
Gas Chromatography
|
Perkin Elmer Autosystem XL
|
Temp. range: up to 4500 C;
Thermal conductivity and Flame ionization detectors; BP1, BP5, BP225 capillary columns; Gas sampling valve accessory; Packed/ capillary column injector
|
Separation of closely related chemical species; qualitative/quantitative analysis; residual solvent present in drugs and monomer in polymer etc.
|
Working
|
Converner : Dr. Sanjay Patel
Contact No : 02692-234966
Email Id : sicart_cvm@hotmail.com
Technical Staff : Dr. Mokshapani Tiwari
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
Liquid Chromatograph Mass Spectrometer
|
Thermo Scientific
LCQ Fleet, TSQ
Quantum Access
|
ESI and APCI source
Mass range: LCQ Fleet: 50-2000 Daltons, TSQ: 30-3000 Daltons. Software’s Bioworks: Protein and Peptides Molecule weight Studies. Met works: Metabolites studies.
LCQ Fleet: Mass fragmentation of compounds up to n10.
|
Separation, Identification and Molecular wt. determination of amino acids, protein, peptides, residual pesticides and non volatile compounds etc. Impurity profile studies of drugs.
|
Working
|
Technical Staff : Mr. Dipen Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
3 | Microscopy |
|
FEG Scanning Electron Microscope
|
FEI Ltd.
Nova NanoSEM 450
|
Resolution:
1.0nm at 15kV
1.4nm at 1kV
3.5nm at 100V
Accelerating Voltage: 20V to 30kV
Beam current: upto 200nA
Magnification: X25 to X10,00,000
|
|
Working
|
Converner : Dr. Sanjay Patel
Contact No : 02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
Scanning Electron Microscope
|
Philips XL30 ESEM
|
Environmental SEM, HV and LV modes of operation;
Magnification: upto 4,50,000x; GSED detector;
EDAX detector;
Carbon coating unit
|
Surface topographic/morphological studies of microstructures on bulk specimens; Study of hydrated samples, non-conducting samples, biological samples in uncoated form through ESEM mode; Detection of Boron onwards all elements.
|
|
Converner : Dr. Sanjay Patel
Contact No : 02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
Transmission Electron Microscope
|
Philips
Tecnai 20
|
Resolution : upto 2 0A;
Acc. voltage: 200 kV;
Magnification: upto 7,50,000x
Ultramicrotome
|
Morphology, Crystal stricture and particle size measurement etc.
Study of ultrastructures of biological/non-biological samples. Liposomes, virus and bacteria study also carried out.
|
Working
|
Converner : Mr. Vikas Patel
Contact No : 02692234966
Email Id : sicart_cvm@hotmail.com
|
4 | Optical Spectroscopy/Other Optical Methods |
|
UV-VIS-NIR Spectrometer
|
Perkin Elmer
Lambda 19
|
Range: 180-3200 nm;
Diffuse reflectance attachment; Colour matching software;
Standards for wavelength and absorption calibration validation traceable to NIST
|
All types of measurements/studies in the region including Absorbance, Transmission and Reflectance spectra; Quantitative analysis.
|
Working
|
Technical Staff : Ms. Dhanvi Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
FT-IR Spectrometer
|
Perkin Elmer
Spectrum GX
|
Range: 30-15600 cm-1;
ATR accessory for reflectance measurement;
IR Quant software;
Spectrum search software
|
Identification and functional groups of organic/ inorganic, biological and polymer compounds etc.
|
Working
|
Technical Staff : Ms. Daxa Patel
Contact No : 02692-234966
Email Id : sicart_cvm@hotamil.com
|
|
Laser Particle Size Analyzer
|
Symantec
Helos BF
|
Range: 0.1 to 875 microns;
32 element array detector;
Accessories for dry powders, pastes, liquids and small sample quantities
|
Particle size distributions curve; density distributions etc.
|
Working
|
Technical Staff : Mr. Savan Patel
Contact No : 02692234966
Email Id : sicart_cvm@hotmail.com
|
|
Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES)
|
Optima-3300 RL
Perkin Elmer, U.S.A.
|
Specifications:
Simultaneous Detection
RF frequency: 40 MHz.
RF Power: 750 to 1500 watts
Pump: 3-channel peristaltic pump 0.2 to 2.5 ml/min in 0.1ml increments
Spectrometer: 6000 pixel SCD Detector, 5000 Emission line resolution
Range: 165 to 782 nm for UV & VIS
Results: 60 elements can be detected in 1 min.
|
|
Working
|
Technical Staff : Mr. Kartik Patel
Contact No : 02692234966
Email Id : sicart_cvm@hotmail.com
|
5 | Other Areas/Facilities |
|
Universal Testing Machine
|
Simadzu
AG 100 KNG
|
Range: 1 kgf to 10,000 kgf
load cells
|
Bending, compression, Tensile & Inter laminar shear testing of materials.
|
Working
|
Technical Staff : Mr. Hardik Parekh
Contact No : 02692234966
Email Id : sicart_cvm@hotmail.com
|
|
Mercury Porosimeter
|
Thermoquest Pascal 440 & 140
|
Range: 400 Kpa to 400 Mpa
|
Analysis including pore size/volume distribution, bulk density and specific surface for porous solids.
|
Non Functional
|
Converner : Mr. Vipul Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
Liquid Nitrogen Plant
|
Sterling
PLN 108S
|
Production capacity: 8 lts per hr.
|
Liquid nitrogen for R&D work.
|
Non Functional
|
Technical Staff : Mr. Amit Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
Deionized Water Plant
|
Millipore
ELIX 3, 10 and Milli Q
|
HPLC grade water quality;
Production capacity: 10 lts. per hr.
|
Deionised water for R&D work.
|
Working
|
|
|
Micro Hardness Tester
|
Shimadzu HMV 2T
|
Load range: 20 gms to 2 kg; Knoop and Vicker’s indenter; 35 mm camera attachment
|
Measurement of surface hardness, hardness of coating as well as parent material.
|
Non Functional
|
Converner : Dr. Sanjay Patel
Contact No : 02692-234966
Email Id : sicart_cvm@hotmail.com
|
6 | Resonance Methods (NMR/EPR/Mossbaur Spectroscopy) |
|
FT-NMR Spectrometer
|
Bruker
AVANCE –III
|
400 MHz machine with 5 mm probe: capable of liquid and solid sample for proton, carbon, fluorine, phosphorus and other nuclei. Solid State NMR with 4mm rotor for multi-nuclei analysis. Temperature range from -800C to +1000C
|
Structure identification of organic, inorganic and polymer materials.
1D and 2D NMR Spectra of all active nuclei, DEPT, APT, COSY, COSY with and without gradient, TOCSY, NOESY, HMQC, HMBC.
|
Working
|
Technical Staff : Dr. Gautam Chauhan
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
7 | Thermal Analysis System |
|
Thermal Analyzer (DSC, TGA)
|
Perkin Elmer
Pyris1 DSC,
Pyris1 TGA,
|
Temp. range:
TGA: RT to 1000 oC
DSC: -50 to 550 oC
|
All types of thermal analysis studies/testing; Thermodynamics, thermal stability, degradation kinetics and quaring kinetics etc.
|
Working
|
Technical Staff : Ms. Dhanvi Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
8 | X-Ray based Methods |
|
X-Ray Fluorescence Spectrometer (WD-XRF)
|
PANalytical, Netherland
AxiosMAX
|
Description: 4Kw, WD-XRF Basic system
|
|
|
Technical Staff : Dr. Mokshapani Tiwari
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|
|
X-Ray Diffractometer (Powder)
|
Philips
Xpert MPD
|
Range (2θ): 20 to 1350;
X-ray tube: Cu;
JCPDS database;
|
2θ vs intensity plots/X-ray diffractograms; search match facility with JCPDS data for qualitative analysis.
|
Working
|
Converner : Mr. Vipul Patel
Contact No : +91-02692-234966
Email Id : sicart_cvm@hotmail.com
|